Why Mathematics? | Optical Interferometry, Fringe Counting and Phase Unwrapping

Three learners review open books together at a classroom table, with stacks of textbooks, stationery and a whiteboard in the bright room.

Why is mathematics important in optical interferometry? Because a camera records brightness, while the quantity of interest may be a path difference far smaller than a visible ruler division. Two coherent waves combine according to phase. Mathematics converts their fringes into displacement, surface shape or refractive information—and warns when phase wraps hide whole wavelengths.

This article is educational, not a laboratory procedure. Lasers can harm eyes, precision setups require trained supervision, and metrology results require calibrated wavelength, geometry, optics, detectors and uncertainty analysis.


Quick Reading Route


Superposition, Phase and Optical Path

Represent two waves at a detector as E1=A1cos(ωt+φ1) and E2=A2cos(ωt+φ2). A detector typically averages optical-frequency power, producing intensity

I=I1+I2+2√(I1I2)cosΔφ,

where Δφ=φ2−φ1. Brightness depends on relative phase, not simply on adding intensities.

Optical phase relates to optical path length OPL=∫n ds. For uniform refractive index n and physical length L, OPL=nL. Phase difference is Δφ=2π(OPD/λ0), where OPD is optical path difference and λ0 is vacuum wavelength under the stated convention.

Did You Know? A mirror can double the path change

In a simple round-trip arm, moving a mirror by Δx changes the outbound and return path, giving OPD≈2Δx. One full fringe cycle corresponds to OPD change λ, so mirror motion λ/2 can produce one cycle. Geometry must be established before using the factor.

Coherence

Stable fringes require sufficient coherence across the path difference and measurement time. Finite spectral width reduces visibility for large delay. Spatial coherence and alignment also matter. The cosine equation assumes fields that overlap at the detector.


How Fringes Encode Path Difference

Constructive interference occurs near Δφ=2πm; destructive interference near Δφ=(2m+1)π. Adjacent equal-phase fringes differ by one integer order. Counting fringes tracks change, while absolute order may remain unknown.

Fringe visibility

Visibility V=(Imax−Imin)/(Imax+Imin). For perfectly coherent balanced beams it can approach one. If intensities are 9 and 4 arbitrary units, Imax=(3+2)²=25 and Imin=(3−2)²=1, so V=24/26≈0.923. Unequal beams reduce contrast even without noise.

Tilt creates straight fringes

If OPD changes approximately linearly with position x, phase is φ(x)=kx+b and intensity is sinusoidal across the image. Fringe spacing is 2π/|k| in spatial units. Greater relative tilt makes phase change faster and fringes closer together.

Curvature bends fringes

A curved wavefront introduces quadratic or more complex phase. Circular fringes can arise from spherical curvature or thickness variation. Shape inference requires the optical geometry; a circular pattern is not a universal diagnosis.

NIST’s phase-measuring interferometer spatial-calibration work notes that a CCD samples the interference pattern at detector elements and that optical magnification determines spatial sampling. Pixels are part of the measurement model.


Phase Stepping and Complex Representation

Instead of locating fringe centres by eye, phase-shifting interferometry records several images while adding known reference phases. For ideal equally spaced steps, each pixel’s intensity can be modelled I_k=a+b cos(φ+δ_k).

With four steps δ=0, π/2, π, 3π/2, one common ideal formula is:

X=I0−Iπ=2b cosφ,

Y=I3π/2−Iπ/2=2b sinφ,

φ=atan2(Y,X).

Scaling and sign vary with step order and convention. A wrong step or vibration between frames biases phase.

Background and modulation

The mean of the four intensities estimates background a. The magnitude √(X²+Y²) relates to modulation. Pixels with low modulation have unreliable phase even if atan2 returns a colour.

More steps and least squares

With many phase steps, write I_k=a+c cosδ_k+d sinδ_k and fit a,c,d by least squares. Then phase follows from atan2 under convention. Redundancy permits residual checks for nonlinearity, motion or incorrect steps.

NIST precision examples

NIST reports phase-measuring interferometry for precision optics with systematic-error accounting, and an advanced phasemeter for very small path sensitivities. These examples demonstrate that phase mathematics is paired with careful instrument characterisation.


Worked Example: Mirror Motion and Fringe Counting

Suppose a Michelson-style arm uses λ=632.8 nm and a mirror moves 1.582 μm along the beam. In a two-pass geometry, OPD change is 2×1.582=3.164 μm. Number of cycles N=3.164 μm/0.6328 μm=5.00.

The detector at a fixed point experiences five full brightness cycles, assuming stable alignment and continuous counting. Reversing motion reverses phase direction but not the absolute number of cycles.

Partial cycle

If motion is 1.50 μm, N=3.00/0.6328≈4.741 cycles. Counting only bright peaks would lose the fractional phase. Quadrature measurement can estimate it: fractional phase is 0.741×2π≈4.66 rad modulo 2π.

Wavelength uncertainty

If wavelength uncertainty is ±0.1 nm, displacement scale inherits about 0.1/632.8≈0.0158% relative uncertainty, before geometry and counting errors. For 1.582 μm that contribution is roughly 0.25 nm. Correlated wavelength error affects all counts systematically.

Missed fringe

One missed full cycle changes inferred mirror motion by λ/2≈316.4 nm in this geometry. That error can dwarf sub-fringe precision. Robust systems track continuity, direction and signal quality rather than relying on final wrapped phase alone.


Wrapped Phase and Phase Unwrapping

atan2 returns phase within an interval such as (−π,π]. A true phase ramp crossing π jumps numerically to −π. Wrapped phase contains local phase but loses the integer multiple of 2π.

Write φ_true=φ_wrapped+2πk, where k is an integer field. Phase unwrapping estimates k using continuity, quality and sometimes multiple wavelengths or models.

One-dimensional rule

A simple algorithm compares neighbouring samples. If a difference exceeds +π, subtract 2π from subsequent phase; if below −π, add 2π. This works when true change between samples is less than π and noise is modest.

Why it fails

At discontinuities, shadows, low contrast or undersampling, neighbouring phase may genuinely differ by more than π. Noise near the boundary can trigger a false cycle. In two dimensions, errors can propagate along the chosen path.

Quality-guided methods

Algorithms may unwrap reliable high-contrast regions first, avoid masked pixels and reconcile loops. A residue indicates inconsistent phase differences around a closed cell. Branch cuts or optimisation methods manage these inconsistencies.

Absolute versus relative measurement

Unwrapping recovers continuity under assumptions; it may not establish absolute order. Multi-wavelength or low-coherence techniques can extend the non-ambiguity range. NIST’s low-coherence optical ranging work illustrates frequency-domain phase-slope methods for locating reflections.


From Phase to Surface Height

Conversion depends on geometry. For normal-incidence reflection with a double pass, height difference h may relate to phase by h=λφ/(4π) after unwrapping and sign convention. Transmission through a sample involves refractive index and thickness; phase may represent their product rather than either alone.

Remove piston and tilt carefully

“Piston” is a constant phase offset; “tilt” is a fitted plane. Subtracting them can reveal surface departure, but it also removes real alignment information. Preserve raw and detrended maps and state the fitting region.

Reference surface

Interferometry measures difference between test and reference wavefronts. Reference optic error, retrace error and imaging distortion can appear in the result. Absolute testing uses reversals or multiple configurations to separate contributions.

Refractive index

Air index changes with temperature, pressure, humidity and composition. For long precision paths, environmental compensation matters. A geometric displacement is not identical to optical path without index knowledge.


Sampling, Filtering and Image Mathematics

A fringe period should span enough pixels to avoid aliasing and estimate phase robustly. Near two pixels per cycle, direction and phase become fragile. Optical blur, pixel integration and camera nonlinearity affect contrast and harmonic content.

Fourier view

A regular fringe appears as peaks in the spatial-frequency domain. Fourier filtering can isolate a carrier and recover phase, but windowing and overlapping spectra influence accuracy. Cropping an image multiplies it by a window and spreads spectral content.

Masks

Pixels with saturation, low modulation or obstruction should be masked using predefined rules. Filling gaps by interpolation creates modelled values. The map must distinguish observed from reconstructed pixels.

Phase noise to height noise

If phase standard deviation is 0.01 rad, reflection height noise under h=λφ/(4π) at 632.8 nm is about 0.503 nm. This calculation is local and incomplete: correlated spatial error and systematics may dominate broader surface shape.


Uncertainty, Sampling and Systematic Error

An interferometric uncertainty budget can include wavelength, phase-step calibration, detector nonlinearity, reference surface, retrace, vibration, air index, temperature, sampling, unwrapping and fitting choices.

Random noise versus systematic structure

Averaging repeated maps can reduce uncorrelated camera noise. It will not remove a stable reference-surface error. Rotating or reversing components can help separate system from test object under an appropriate model.

Repeatability is not accuracy

Beautifully repeated fringes may share the same wavelength or geometry bias. Traceability requires calibrated references and uncertainty, not visual stability alone.

Speckle and coherence artefacts

Coherent illumination can produce speckle from rough surfaces and stray reflections. These are physical interference effects, not simple Gaussian pixel noise. Optical design and surface preparation matter.

Reporting

State wavelength, geometry, phase algorithm, unwrap method, reference, environmental correction, mask, sampling and uncertainty. A nanometre result without that context is merely a number with an impressive unit.


Misconceptions Worth Correcting

“One fringe equals one wavelength of mirror motion”

Not in a two-pass reflection geometry: mirror motion is commonly half the OPD change. Derive the path factor.

“Phase is measured absolutely”

Many methods recover phase modulo 2π. Absolute order needs additional information.

“A smooth unwrap must be correct”

Algorithms can create smooth but cycle-shifted regions. Quality maps and consistency checks are essential.

“More coherent light is always better”

High coherence supports long path differences but can increase parasitic fringes and speckle. The source must suit the task.

“The camera directly measures height”

It measures intensity. Height is inferred through interference, phase recovery, unwrapping and a geometry model.


Learning Pathways for Students

Interferometry connects waves, trigonometry, complex numbers, modular arithmetic, sampling, matrices and optimisation. A student can simulate fringes safely in code, explore wrapping and test algorithms without a laser.

Four-week plan

  • Week 1: waves, phase, optical path and intensity;
  • Week 2: fringe geometry, visibility and phase stepping;
  • Week 3: wrapping, sampling, Fourier methods and masks;
  • Week 4: surface conversion, uncertainty and an auditable report.

The career pathways include optics, semiconductor manufacturing, astronomy, precision engineering and imaging. Mathematics keeps these routes open but does not substitute for laboratory training.


Frequently Asked Questions

What creates a bright fringe?

Relative phase makes the fields add constructively at that location, subject to beam overlap and coherence.

Why does moving a mirror change brightness?

It changes optical path and therefore relative phase between the arms.

What is optical path difference?

It is the difference between refractive-index-weighted path lengths of the interfering waves.

Why use phase instead of counting lines?

Phase can recover fractional-fringe information at every valid pixel and support dense maps.

What is wrapped phase?

It is phase reduced to one 2π interval, so different absolute phases can share the same displayed value.

Can unwrapping always recover truth?

No. It needs sufficient sampling, continuity or extra constraints. Discontinuities and low signal create ambiguity.

Why use more than one wavelength?

Their beat or synthetic wavelength can extend the non-ambiguity range, with new calibration and noise trade-offs.

Does one pixel equal one surface point?

It represents an area filtered by optics and pixel response. Magnification and distortion determine spatial mapping.

Why subtract tilt?

It can isolate form from alignment, but the removed component must be reported and preserved.

What is fringe visibility?

It is a contrast measure using maximum and minimum intensity. Low visibility usually means phase is less reliable.

Is nanometre sensitivity the same as nanometre accuracy?

No. Sensitivity or resolution can be much smaller than total uncertainty from systematics and calibration.

What is the transferable lesson?

Periodic measurements are powerful but ambiguous by whole cycles; mathematics must track both fine phase and integer order.


Useful Next Reading

Read Why Mathematics? | Gauge Blocks, Calibration Chains and Measurement Uncertainty for traceability. Why Mathematics? | Strain Gauges, Wheatstone Bridges and Measurement Sensitivity shows another indirect measurement chain. Why Mathematics? | Typography, Kerning, Baselines and Optical Spacing offers a very different meaning of optical judgement.

The joyful insight is that a bright and dark pattern can become a precision ruler. Mathematics makes the conversion possible—and keeps the whole-wavelength ambiguities visible.


A Practical Investigation Studio

These activities use synthetic or openly released teaching data. They are designed to make every assumption visible. For each investigation, begin with a labelled diagram or data dictionary, keep unrounded intermediate values, and finish with a short limitation statement. The goal is not to imitate a professional instrument with a spreadsheet; it is to understand which mathematical operation gives the instrument its meaning.

Investigation 1: Path-difference map

Calculate phase for several optical path differences using one wavelength. Reduce phase modulo 2π but keep the unreduced path values for comparison. Include one graph or table, one dimensional or limiting-case check, and one paragraph separating the calculated result from the real-world conclusion. Change one input across a sensible range to test sensitivity. If the result changes sharply, report the instability instead of hiding it with extra decimal places. Preserve the original data and record every correction so a classmate can audit the route from measurement to claim. Before calculating, predict the direction of change and explain the physical reason. After calculating, compare the prediction with the result and investigate any disagreement. Repeat the analysis with one deliberately flawed input—wrong unit, reversed sign, missing sample or premature rounding—and describe how the error appears. This makes the activity an error-detection exercise rather than a search for one polished answer. Finish by naming which quantities were observed, which were assumed, which were fitted and which were derived. State the domain over which the model is credible and one condition that would require a richer model. A strong submission includes the raw synthetic data, formulas or code, labelled axes, units, intermediate checks, final result, uncertainty note and a concise explanation suitable for a younger student. Do not claim professional validation from a classroom simulation.

Investigation 2: Fringe counting

Move a mirror in a two-pass geometry and count predicted bright-to-bright cycles. Explain the factor of two before inserting numbers. Include one graph or table, one dimensional or limiting-case check, and one paragraph separating the calculated result from the real-world conclusion. Change one input across a sensible range to test sensitivity. If the result changes sharply, report the instability instead of hiding it with extra decimal places. Preserve the original data and record every correction so a classmate can audit the route from measurement to claim. Before calculating, predict the direction of change and explain the physical reason. After calculating, compare the prediction with the result and investigate any disagreement. Repeat the analysis with one deliberately flawed input—wrong unit, reversed sign, missing sample or premature rounding—and describe how the error appears. This makes the activity an error-detection exercise rather than a search for one polished answer. Finish by naming which quantities were observed, which were assumed, which were fitted and which were derived. State the domain over which the model is credible and one condition that would require a richer model. A strong submission includes the raw synthetic data, formulas or code, labelled axes, units, intermediate checks, final result, uncertainty note and a concise explanation suitable for a younger student. Do not claim professional validation from a classroom simulation.

Investigation 3: Intensity model

Plot I=I1+I2+2 sqrt(I1I2) cos phi for balanced and unbalanced beams. Compare visibility and show why unequal intensities reduce contrast. Include one graph or table, one dimensional or limiting-case check, and one paragraph separating the calculated result from the real-world conclusion. Change one input across a sensible range to test sensitivity. If the result changes sharply, report the instability instead of hiding it with extra decimal places. Preserve the original data and record every correction so a classmate can audit the route from measurement to claim. Before calculating, predict the direction of change and explain the physical reason. After calculating, compare the prediction with the result and investigate any disagreement. Repeat the analysis with one deliberately flawed input—wrong unit, reversed sign, missing sample or premature rounding—and describe how the error appears. This makes the activity an error-detection exercise rather than a search for one polished answer. Finish by naming which quantities were observed, which were assumed, which were fitted and which were derived. State the domain over which the model is credible and one condition that would require a richer model. A strong submission includes the raw synthetic data, formulas or code, labelled axes, units, intermediate checks, final result, uncertainty note and a concise explanation suitable for a younger student. Do not claim professional validation from a classroom simulation.

Investigation 4: Phase stepping

Sample four equally spaced phase steps and recover sine and cosine components. Test sensitivity to one incorrect step and detector offset. Include one graph or table, one dimensional or limiting-case check, and one paragraph separating the calculated result from the real-world conclusion. Change one input across a sensible range to test sensitivity. If the result changes sharply, report the instability instead of hiding it with extra decimal places. Preserve the original data and record every correction so a classmate can audit the route from measurement to claim. Before calculating, predict the direction of change and explain the physical reason. After calculating, compare the prediction with the result and investigate any disagreement. Repeat the analysis with one deliberately flawed input—wrong unit, reversed sign, missing sample or premature rounding—and describe how the error appears. This makes the activity an error-detection exercise rather than a search for one polished answer. Finish by naming which quantities were observed, which were assumed, which were fitted and which were derived. State the domain over which the model is credible and one condition that would require a richer model. A strong submission includes the raw synthetic data, formulas or code, labelled axes, units, intermediate checks, final result, uncertainty note and a concise explanation suitable for a younger student. Do not claim professional validation from a classroom simulation.

Investigation 5: Wrapped ramp

Create a linear phase ramp that crosses several 2π boundaries. Plot wrapped and unwrapped versions and mark every integer-cycle decision. Include one graph or table, one dimensional or limiting-case check, and one paragraph separating the calculated result from the real-world conclusion. Change one input across a sensible range to test sensitivity. If the result changes sharply, report the instability instead of hiding it with extra decimal places. Preserve the original data and record every correction so a classmate can audit the route from measurement to claim. Before calculating, predict the direction of change and explain the physical reason. After calculating, compare the prediction with the result and investigate any disagreement. Repeat the analysis with one deliberately flawed input—wrong unit, reversed sign, missing sample or premature rounding—and describe how the error appears. This makes the activity an error-detection exercise rather than a search for one polished answer. Finish by naming which quantities were observed, which were assumed, which were fitted and which were derived. State the domain over which the model is credible and one condition that would require a richer model. A strong submission includes the raw synthetic data, formulas or code, labelled axes, units, intermediate checks, final result, uncertainty note and a concise explanation suitable for a younger student. Do not claim professional validation from a classroom simulation.

Investigation 6: Noisy unwrap

Add noise near the ±π boundary. Identify when a local jump rule makes a cycle error and why spatial context helps. Include one graph or table, one dimensional or limiting-case check, and one paragraph separating the calculated result from the real-world conclusion. Change one input across a sensible range to test sensitivity. If the result changes sharply, report the instability instead of hiding it with extra decimal places. Preserve the original data and record every correction so a classmate can audit the route from measurement to claim. Before calculating, predict the direction of change and explain the physical reason. After calculating, compare the prediction with the result and investigate any disagreement. Repeat the analysis with one deliberately flawed input—wrong unit, reversed sign, missing sample or premature rounding—and describe how the error appears. This makes the activity an error-detection exercise rather than a search for one polished answer. Finish by naming which quantities were observed, which were assumed, which were fitted and which were derived. State the domain over which the model is credible and one condition that would require a richer model. A strong submission includes the raw synthetic data, formulas or code, labelled axes, units, intermediate checks, final result, uncertainty note and a concise explanation suitable for a younger student. Do not claim professional validation from a classroom simulation.

Investigation 7: Sampling fringes

Represent a sinusoidal fringe at different pixels per period. Connect undersampling with aliasing and lost direction information. Include one graph or table, one dimensional or limiting-case check, and one paragraph separating the calculated result from the real-world conclusion. Change one input across a sensible range to test sensitivity. If the result changes sharply, report the instability instead of hiding it with extra decimal places. Preserve the original data and record every correction so a classmate can audit the route from measurement to claim. Before calculating, predict the direction of change and explain the physical reason. After calculating, compare the prediction with the result and investigate any disagreement. Repeat the analysis with one deliberately flawed input—wrong unit, reversed sign, missing sample or premature rounding—and describe how the error appears. This makes the activity an error-detection exercise rather than a search for one polished answer. Finish by naming which quantities were observed, which were assumed, which were fitted and which were derived. State the domain over which the model is credible and one condition that would require a richer model. A strong submission includes the raw synthetic data, formulas or code, labelled axes, units, intermediate checks, final result, uncertainty note and a concise explanation suitable for a younger student. Do not claim professional validation from a classroom simulation.

Investigation 8: Wavelength sensitivity

Repeat a displacement calculation with a small wavelength uncertainty. Propagate it to path uncertainty and state whether it is systematic across pixels. Include one graph or table, one dimensional or limiting-case check, and one paragraph separating the calculated result from the real-world conclusion. Change one input across a sensible range to test sensitivity. If the result changes sharply, report the instability instead of hiding it with extra decimal places. Preserve the original data and record every correction so a classmate can audit the route from measurement to claim. Before calculating, predict the direction of change and explain the physical reason. After calculating, compare the prediction with the result and investigate any disagreement. Repeat the analysis with one deliberately flawed input—wrong unit, reversed sign, missing sample or premature rounding—and describe how the error appears. This makes the activity an error-detection exercise rather than a search for one polished answer. Finish by naming which quantities were observed, which were assumed, which were fitted and which were derived. State the domain over which the model is credible and one condition that would require a richer model. A strong submission includes the raw synthetic data, formulas or code, labelled axes, units, intermediate checks, final result, uncertainty note and a concise explanation suitable for a younger student. Do not claim professional validation from a classroom simulation.

Investigation 9: Tilt and curvature

Fit a plane to a phase map, subtract it and inspect the residual surface. Explain which physical feature the removed plane represents and preserve both maps. Include one graph or table, one dimensional or limiting-case check, and one paragraph separating the calculated result from the real-world conclusion. Change one input across a sensible range to test sensitivity. If the result changes sharply, report the instability instead of hiding it with extra decimal places. Preserve the original data and record every correction so a classmate can audit the route from measurement to claim. Before calculating, predict the direction of change and explain the physical reason. After calculating, compare the prediction with the result and investigate any disagreement. Repeat the analysis with one deliberately flawed input—wrong unit, reversed sign, missing sample or premature rounding—and describe how the error appears. This makes the activity an error-detection exercise rather than a search for one polished answer. Finish by naming which quantities were observed, which were assumed, which were fitted and which were derived. State the domain over which the model is credible and one condition that would require a richer model. A strong submission includes the raw synthetic data, formulas or code, labelled axes, units, intermediate checks, final result, uncertainty note and a concise explanation suitable for a younger student. Do not claim professional validation from a classroom simulation.

Investigation 10: Visibility metric

Calculate (Imax-Imin)/(Imax+Imin) for several pairs. Avoid division when the denominator is near zero and report detector limits. Include one graph or table, one dimensional or limiting-case check, and one paragraph separating the calculated result from the real-world conclusion. Change one input across a sensible range to test sensitivity. If the result changes sharply, report the instability instead of hiding it with extra decimal places. Preserve the original data and record every correction so a classmate can audit the route from measurement to claim. Before calculating, predict the direction of change and explain the physical reason. After calculating, compare the prediction with the result and investigate any disagreement. Repeat the analysis with one deliberately flawed input—wrong unit, reversed sign, missing sample or premature rounding—and describe how the error appears. This makes the activity an error-detection exercise rather than a search for one polished answer. Finish by naming which quantities were observed, which were assumed, which were fitted and which were derived. State the domain over which the model is credible and one condition that would require a richer model. A strong submission includes the raw synthetic data, formulas or code, labelled axes, units, intermediate checks, final result, uncertainty note and a concise explanation suitable for a younger student. Do not claim professional validation from a classroom simulation.

Investigation 11: Synthetic wavelength

Combine two close wavelengths in a beat calculation. Describe the larger non-ambiguity scale and the cost in sensitivity or calibration. Include one graph or table, one dimensional or limiting-case check, and one paragraph separating the calculated result from the real-world conclusion. Change one input across a sensible range to test sensitivity. If the result changes sharply, report the instability instead of hiding it with extra decimal places. Preserve the original data and record every correction so a classmate can audit the route from measurement to claim. Before calculating, predict the direction of change and explain the physical reason. After calculating, compare the prediction with the result and investigate any disagreement. Repeat the analysis with one deliberately flawed input—wrong unit, reversed sign, missing sample or premature rounding—and describe how the error appears. This makes the activity an error-detection exercise rather than a search for one polished answer. Finish by naming which quantities were observed, which were assumed, which were fitted and which were derived. State the domain over which the model is credible and one condition that would require a richer model. A strong submission includes the raw synthetic data, formulas or code, labelled axes, units, intermediate checks, final result, uncertainty note and a concise explanation suitable for a younger student. Do not claim professional validation from a classroom simulation.

Investigation 12: Audit trail

Record wavelength, geometry, sign, reference surface, phase algorithm and mask. Have another student reproduce one height difference without seeing the final answer. Include one graph or table, one dimensional or limiting-case check, and one paragraph separating the calculated result from the real-world conclusion. Change one input across a sensible range to test sensitivity. If the result changes sharply, report the instability instead of hiding it with extra decimal places. Preserve the original data and record every correction so a classmate can audit the route from measurement to claim. Before calculating, predict the direction of change and explain the physical reason. After calculating, compare the prediction with the result and investigate any disagreement. Repeat the analysis with one deliberately flawed input—wrong unit, reversed sign, missing sample or premature rounding—and describe how the error appears. This makes the activity an error-detection exercise rather than a search for one polished answer. Finish by naming which quantities were observed, which were assumed, which were fitted and which were derived. State the domain over which the model is credible and one condition that would require a richer model. A strong submission includes the raw synthetic data, formulas or code, labelled axes, units, intermediate checks, final result, uncertainty note and a concise explanation suitable for a younger student. Do not claim professional validation from a classroom simulation.