VIEW THIS AS

Auto mode follows the Route Engine until you choose a viewpoint.

YOU ARE HERE

ROUTE CHECK

CONNECTED TO

WHAT NEXT

Use the canonical route for this room, or HELP if you are unsure.

Why Science? | HIC Indexed Chromatin Contact Matrices

Three students sit around open books and worksheets at a classroom table, reading, writing and discussing the work together.

eduKateSG · Why Science?

Explore dense chromatin contact matrices by region—while preserving assembly, bins, resolution, normalisation, distance effects and causal limits

Choose the closest route, then return to the full index whenever you need the wider evidence chain.

Full section index · Science Learning Hub

Science learning becomes powerful when students can tell a measured pattern from a model, a statistical decision from a mechanism, and a useful lead from a finished conclusion. UCSC HIC tracks read indexed binary .hic files for rapid regional access to dense chromatin-contact matrices and currently support file versions 6 through 8. The format was designed by the Aiden Lab and is commonly produced from Hi-C or in situ Hi-C workflows through software such as Juicer. A track uses type hic and a web-accessible bigDataUrl; large files are not directly uploaded. Users can choose square, triangle or arc display, matrix resolution and normalisation including NONE, VC, VC_SQRT and KR. Contact intensity reflects an assay- and processing-dependent count or score, not a fixed physical distance, regulatory direction or causal mechanism. This guide supports Primary Science, PSLE Science, Secondary Science, O-Level Science and STEM education as a longform evidence-reading route; it is not medical advice, a laboratory protocol, an admission promise or a career guarantee.

Related eduKate reading: Hi-C proximity ligation and three-dimensional genome contact evidence; interact and bigInteract genomic interaction tracks; bigWig indexed genomic signal tracks; Science Learning Hub; Education Hub; STEM Education; Careers by Subject Capability.

Primary and official sources checked on 12 October 2026: UCSC Genome Browser HIC Track Format, checked 12 October 2026; UCSC Genome Browser HIC Track Configuration, checked 12 October 2026; UCSC Genome Browser interact and bigInteract Track Format, checked 12 October 2026; 2026 Singapore–Cambridge O-Level Biology syllabus; MOE G2/G3 Lower Secondary Science teaching and learning syllabus; 2026 MOE G2 Computing syllabus. Specifications, tools and recommendations can change, so preserve dated documentation, exact source data, coordinate rules and software versions.

A deeper reading route

A dense Hi-C experiment produces relationships among many pairs of genomic bins. Listing every pair as an arc quickly becomes unwieldy, so the HIC format stores contact matrices with indexes that allow a browser to retrieve relevant regions and resolutions. UCSC explicitly distinguishes this high-density use from interact or bigInteract, which better suit sparse pairwise relationships.

The matrix is organised by genomic bins. Resolution defines bin width, so a lower numeric bin size can show finer structure but usually has fewer observations per cell and greater noise. A contact in a coarse matrix aggregates many finer pairs. Analysts should never compare cell values across resolutions without explaining the aggregation and coverage consequences.

The matrix is usually symmetric for an undirected Hi-C contact count: contact between bin A and bin B is the same pair as B and A. Storage and display can exploit that symmetry, yet interpretation still depends on which genomic region occupies each axis. Axis labels, assembly and bin edges must remain visible, especially when comparing two regions or chromosomes.

Normalisation attempts to reduce systematic biases. UCSC exposes NONE, VC, VC_SQRT and KR when available in the file. Each option applies a different transformation or balancing approach, and some resolutions or chromosomes may lack a successful normalisation vector. A methods note should name the selected method and report unavailable or failed cases rather than silently falling back.

Genomic distance is a major structural effect: nearby loci tend to produce more contacts than distant loci in bulk Hi-C. A bright near-diagonal signal can therefore arise from polymer and assay geometry rather than a specific regulatory loop. Distance-aware background models and replicate evidence are needed before interpreting a cell as an exceptional biological interaction.

UCSC offers square, triangle and arc displays. Square and triangle views organise the same matrix geometry differently, while arcs convert selected contact values into connections across one axis. Visual mode changes perception, not evidence. Colour scale, saturation, window, resolution, normalisation and mode all belong in figure provenance.

Automatic scaling sets the saturation maximum using twice the median score in the current window. That is convenient for exploration, but two windows can then assign different colours to the same numeric contact value. Comparative figures need a fixed documented scale, and readers should be able to inspect exact values or exported summaries.

The track stanza requires type hic and bigDataUrl pointing to a web-accessible .hic file. Because files can be very large, UCSC says they are not uploaded directly. Hosting must support stable access and suitable requests, and the public or controlled-access status must match the sensitivity of the samples. Indexed availability is a publication decision.

Assembly identity is essential. A HIC matrix is binned against specific chromosome names, lengths and sequence assembly. Relabelling a file for another assembly does not move contacts. Liftover of matrix information is non-trivial because bins split, merge or fail to map; the original coordinate system and any transformation must remain explicit.

Validation should inspect file version, chromosomes, resolutions, matrix symmetry, expected totals, normalisation availability, representative bins and browser retrieval. Include empty regions, chromosome edges, interchromosomal cells, low-coverage bins and extreme values. Compare a small exported matrix with an independent reader and preserve hashes for the .hic file and source pipeline outputs.

For students, a HIC matrix resembles a timetable where both axes list genomic neighbourhoods and each cell records how often a pair was observed together. Changing bin size is like grouping streets into districts: the picture becomes simpler, but the question changes. This is a joyful bridge between biology, matrices and computing.

A reproducible bundle includes sample and assay metadata, restriction or fragmentation method, reference assembly, mapping and filtering pipeline, valid pairs, matrix-building commands, Juicer or equivalent versions, .hic version and hash, resolutions, normalisation vectors, track stanza, scale settings, quality metrics and a statement separating contact from causality.

Replicates provide evidence that a pattern is not a one-library accident. Compare contact-distance curves, coverage profiles, compartment structure and reproducibility metrics before merging matrices. Biological replicates can differ because of real heterogeneity, while technical differences can arise from digestion, ligation, sequencing depth or mapping. A pooled HIC file should keep the contribution and quality of each source library visible.

Matrix sparsity changes across resolutions and sample sizes. Fine bins may contain many zeros because no read pair was observed, not because two regions can never contact. Zero, missing and masked bins must remain distinct. When smoothing or imputation is used, publish the algorithm and retain the observed matrix so inferred structure is not mistaken for direct measurement.

Comparative contact analysis needs a common basis. Different assemblies, bin boundaries, depth, filtering or normalisation can create apparent changes. Harmonise the coordinate system and pipeline, then use an appropriate statistical model with replicates and multiple-testing control. Side-by-side heatmaps are excellent for exploration but are not, by themselves, a differential-contact test.

Privacy and ethics can extend beyond sequence variants. Cell lines, tissues, disease cohorts and rare sample descriptions can identify or stigmatise groups even when a matrix looks aggregated. Release review should consider metadata, access logs and the possibility of linkage with other datasets. Educational examples should use public, consent-compatible resources and avoid implying medical conclusions.

Long-term reproducibility also requires preserving reader software and defaults. A future browser may support additional HIC versions, normalisation methods or rendering rules. Store a small validation extract and expected values alongside the large binary so later tools can be checked without reconstructing the whole experiment. Compatibility means more than opening the file; it means reproducing the intended matrix cells and interpretation context.

A four-step claim ladder for this method
StageQuestionEvidenceResponsible output
BinWhich genomic intervals define each matrix row and column?Assembly, chromosome names, bin size and resolutionA coordinate-specific matrix
CountWhat contact measurement fills each cell?Valid pairs, filtering and matrix-building rulesAn assay-dependent score
BalanceHow were systematic biases treated?NONE, VC, VC_SQRT, KR and availabilityA documented normalised view
JudgeWhat can a bright cell support?Distance background, replicates, controls and validationA bounded contact claim

Section 1 of 36

1. Start with the contact question

HIC stores dense matrices of assay-derived chromatin contacts.

Working checkpoint — HIC file: Name sample, assay, assembly and intended comparison. Keep assay, sample, assembly, valid pairs, matrix-building pipeline, HIC version, resolutions, normalisation and scale together.

For a classroom model, use a small fictional symmetric matrix at two bin sizes.

Contents · Next section

Section 2 of 36

2. Separate assay from file

Hi-C generates evidence while .hic organises derived matrices for indexed access.

Working checkpoint — Hi-C contact matrix: Preserve source pairs and pipeline. Read every bright cell beside genomic distance, bin size, coverage, replicate evidence and bias treatment.

For future study, connect chromosome folding to biology, physics, matrices and computing while checking official pathways separately.

Contents · Previous section · Next section

Section 3 of 36

3. Use supported versions

UCSC currently documents support for HIC versions 6 through 8.

Working checkpoint — chromatin contact: Record the exact file and reader versions. Preserve low-coverage, failed-normalisation and filtered bins; the colourful matrix is not the complete experiment.

For scientific writing, report assay, assembly, resolution, normalisation, scale, QC and limitations.

Contents · Previous section · Next section

Section 4 of 36

4. Read the chromosome dictionary

Matrix axes depend on assembly-specific chromosome names and lengths.

Working checkpoint — matrix bin: Compare them with the intended reference. Separate indexed retrieval and contact enrichment from physical distance, regulation and causation.

For students, ask what each axis, bin and colour means before interpreting a pattern.

Contents · Previous section · Next section

Section 5 of 36

5. Read bin boundaries

Each row and column represents a genomic bin at a chosen resolution.

Working checkpoint — normalization: Use explicit half-open intervals. Treat assembly, bins, resolution and normalisation as scientific inputs: a silent change can reshape the matrix.

For parents, ask whether a striking heatmap keeps scale, controls and uncertainty visible.

Contents · Previous section · Next section

Section 6 of 36

6. Understand resolution

Smaller bins offer finer detail but usually fewer observations per cell.

Working checkpoint — three-dimensional genome: Compare coverage and noise. Keep assay, sample, assembly, valid pairs, matrix-building pipeline, HIC version, resolutions, normalisation and scale together.

For a classroom model, use a small fictional symmetric matrix at two bin sizes.

Contents · Previous section · Next section

Section 7 of 36

7. Avoid cross-resolution shortcuts

A coarse cell aggregates many fine-bin pairs and is not directly equivalent to one fine cell.

Working checkpoint — HIC file: State the aggregation. Read every bright cell beside genomic distance, bin size, coverage, replicate evidence and bias treatment.

For future study, connect chromosome folding to biology, physics, matrices and computing while checking official pathways separately.

Contents · Previous section · Next section

Section 8 of 36

8. Check matrix symmetry

Undirected contact matrices should agree across mirrored bin pairs within storage conventions.

Working checkpoint — Hi-C contact matrix: Test A-B against B-A. Preserve low-coverage, failed-normalisation and filtered bins; the colourful matrix is not the complete experiment.

For scientific writing, report assay, assembly, resolution, normalisation, scale, QC and limitations.

Contents · Previous section · Next section

Section 9 of 36

9. Inspect diagonal structure

Nearby loci often have higher contact frequency because contact decays with genomic distance.

Working checkpoint — chromatin contact: Model distance before calling an exception. Separate indexed retrieval and contact enrichment from physical distance, regulation and causation.

For students, ask what each axis, bin and colour means before interpreting a pattern.

Contents · Previous section · Next section

Section 10 of 36

10. Inspect interchromosomal values

Contacts across chromosomes have different background and sparsity properties.

Working checkpoint — matrix bin: Use appropriate controls. Treat assembly, bins, resolution and normalisation as scientific inputs: a silent change can reshape the matrix.

For parents, ask whether a striking heatmap keeps scale, controls and uncertainty visible.

Contents · Previous section · Next section

Section 11 of 36

11. Understand raw mode

NONE exposes unnormalised matrix values available in the file.

Working checkpoint — normalization: Keep library depth and biases visible. Keep assay, sample, assembly, valid pairs, matrix-building pipeline, HIC version, resolutions, normalisation and scale together.

For a classroom model, use a small fictional symmetric matrix at two bin sizes.

Contents · Previous section · Next section

Section 12 of 36

12. Understand VC

Vanilla coverage applies coverage-based balancing under file conventions.

Working checkpoint — three-dimensional genome: Name it explicitly. Read every bright cell beside genomic distance, bin size, coverage, replicate evidence and bias treatment.

For future study, connect chromosome folding to biology, physics, matrices and computing while checking official pathways separately.

Contents · Previous section · Next section

Section 13 of 36

13. Understand VC_SQRT

The square-root coverage option applies a related but distinct transformation.

Working checkpoint — HIC file: Do not label it simply normalised. Preserve low-coverage, failed-normalisation and filtered bins; the colourful matrix is not the complete experiment.

For scientific writing, report assay, assembly, resolution, normalisation, scale, QC and limitations.

Contents · Previous section · Next section

Section 14 of 36

14. Understand KR

Knight-Ruiz balancing seeks matrix balance where a vector is available.

Working checkpoint — Hi-C contact matrix: Report failed or absent vectors. Separate indexed retrieval and contact enrichment from physical distance, regulation and causation.

For students, ask what each axis, bin and colour means before interpreting a pattern.

Contents · Previous section · Next section

Section 15 of 36

15. Handle missing normalisation

Not every chromosome and resolution necessarily has every method.

Working checkpoint — chromatin contact: Never silently substitute a method. Treat assembly, bins, resolution and normalisation as scientific inputs: a silent change can reshape the matrix.

For parents, ask whether a striking heatmap keeps scale, controls and uncertainty visible.

Contents · Previous section · Next section

Section 16 of 36

16. Choose square display

Square mode shows the contact matrix across two axes.

Working checkpoint — matrix bin: Label both genomic ranges. Keep assay, sample, assembly, valid pairs, matrix-building pipeline, HIC version, resolutions, normalisation and scale together.

For a classroom model, use a small fictional symmetric matrix at two bin sizes.

Contents · Previous section · Next section

Section 17 of 36

17. Choose triangle display

Triangle mode folds matrix geometry into one genomic span.

Working checkpoint — normalization: Explain orientation and coordinates. Read every bright cell beside genomic distance, bin size, coverage, replicate evidence and bias treatment.

For future study, connect chromosome folding to biology, physics, matrices and computing while checking official pathways separately.

Contents · Previous section · Next section

Section 18 of 36

18. Choose arc display

Arc mode turns matrix relationships into connections for browsing.

Working checkpoint — three-dimensional genome: Avoid implying direction or cause. Preserve low-coverage, failed-normalisation and filtered bins; the colourful matrix is not the complete experiment.

For scientific writing, report assay, assembly, resolution, normalisation, scale, QC and limitations.

Contents · Previous section · Next section

Section 19 of 36

19. Control colour scale

Colour maps numerical values to visual intensity.

Working checkpoint — HIC file: Publish minimum, maximum and palette. Separate indexed retrieval and contact enrichment from physical distance, regulation and causation.

For students, ask what each axis, bin and colour means before interpreting a pattern.

Contents · Previous section · Next section

Section 20 of 36

20. Understand auto-scale

UCSC auto-scale uses twice the median score in the current window as saturation maximum.

Working checkpoint — Hi-C contact matrix: Fix the scale for comparisons. Treat assembly, bins, resolution and normalisation as scientific inputs: a silent change can reshape the matrix.

For parents, ask whether a striking heatmap keeps scale, controls and uncertainty visible.

Contents · Previous section · Next section

Section 21 of 36

21. Use the track stanza

A HIC track declares type hic and a bigDataUrl.

Working checkpoint — chromatin contact: Archive the complete stanza. Keep assay, sample, assembly, valid pairs, matrix-building pipeline, HIC version, resolutions, normalisation and scale together.

For a classroom model, use a small fictional symmetric matrix at two bin sizes.

Contents · Previous section · Next section

Section 22 of 36

22. Host rather than upload

UCSC says large .hic files should be web-accessible rather than directly uploaded.

Working checkpoint — matrix bin: Test stable authorised access. Read every bright cell beside genomic distance, bin size, coverage, replicate evidence and bias treatment.

For future study, connect chromosome folding to biology, physics, matrices and computing while checking official pathways separately.

Contents · Previous section · Next section

Section 23 of 36

23. Match format to density

HIC is appropriate for dense matrices, while interact/bigInteract suit lower-density relationships.

Working checkpoint — normalization: Choose by scientific structure. Preserve low-coverage, failed-normalisation and filtered bins; the colourful matrix is not the complete experiment.

For scientific writing, report assay, assembly, resolution, normalisation, scale, QC and limitations.

Contents · Previous section · Next section

Section 24 of 36

24. Validate representative bins

Check known regions, empty bins, edges and interchromosomal cells with an independent reader.

Working checkpoint — three-dimensional genome: Compare exact values. Separate indexed retrieval and contact enrichment from physical distance, regulation and causation.

For students, ask what each axis, bin and colour means before interpreting a pattern.

Contents · Previous section · Next section

Section 25 of 36

25. Audit totals and quality

A correct browser tile cannot reveal sample swaps, dropped reads or incomplete chromosomes.

Working checkpoint — HIC file: Review mapping and contact QC. Treat assembly, bins, resolution and normalisation as scientific inputs: a silent change can reshape the matrix.

For parents, ask whether a striking heatmap keeps scale, controls and uncertainty visible.

Contents · Previous section · Next section

Section 26 of 36

26. Protect sample privacy

Human contact maps and metadata may be sensitive or unpublished.

Working checkpoint — Hi-C contact matrix: Apply governance before hosting. Keep assay, sample, assembly, valid pairs, matrix-building pipeline, HIC version, resolutions, normalisation and scale together.

For a classroom model, use a small fictional symmetric matrix at two bin sizes.

Contents · Previous section · Next section

Section 27 of 36

27. Separate contact from mechanism

A high score does not prove physical distance, regulatory direction or causal effect.

Working checkpoint — chromatin contact: Require orthogonal evidence. Read every bright cell beside genomic distance, bin size, coverage, replicate evidence and bias treatment.

For future study, connect chromosome folding to biology, physics, matrices and computing while checking official pathways separately.

Contents · Previous section · Next section

Section 28 of 36

28. Connect to Primary Science

A grid of neighbourhood pairs can model repeated observations without using personal data.

Working checkpoint — matrix bin: Count and colour fictional contacts. Preserve low-coverage, failed-normalisation and filtered bins; the colourful matrix is not the complete experiment.

For scientific writing, report assay, assembly, resolution, normalisation, scale, QC and limitations.

Contents · Previous section · Next section

Section 29 of 36

29. Connect to Secondary Science

HIC supports lessons about models, controls, scale, uncertainty and three-dimensional organisation.

Working checkpoint — normalization: Separate measurement from explanation. Separate indexed retrieval and contact enrichment from physical distance, regulation and causation.

For students, ask what each axis, bin and colour means before interpreting a pattern.

Contents · Previous section · Next section

Section 30 of 36

30. Connect to mathematics

Matrices, symmetry, medians, normalisation and spatial scale create precise quantitative practice.

Working checkpoint — three-dimensional genome: Check a small symmetric matrix. Treat assembly, bins, resolution and normalisation as scientific inputs: a silent change can reshape the matrix.

For parents, ask whether a striking heatmap keeps scale, controls and uncertainty visible.

Contents · Previous section · Next section

Section 31 of 36

31. Connect to computing

Indexes, multiresolution data, sparse access and rendering show scientific systems engineering.

Working checkpoint — HIC file: Query the same region at two resolutions. Keep assay, sample, assembly, valid pairs, matrix-building pipeline, HIC version, resolutions, normalisation and scale together.

For a classroom model, use a small fictional symmetric matrix at two bin sizes.

Contents · Previous section · Next section

Section 32 of 36

32. Connect to pathways

Chromatin-contact analysis joins biology, physics, statistics and software and can illuminate STEM education and career pathways.

Working checkpoint — Hi-C contact matrix: Verify current study routes separately. Read every bright cell beside genomic distance, bin size, coverage, replicate evidence and bias treatment.

For future study, connect chromosome folding to biology, physics, matrices and computing while checking official pathways separately.

Contents · Previous section · Next section

Section 33 of 36

33. Did you know?

UCSC can show the same HIC contact data as squares, triangles or arcs, and its automatic scale depends on the current window.

Working checkpoint — chromatin contact: Record mode and scale with every figure. Preserve low-coverage, failed-normalisation and filtered bins; the colourful matrix is not the complete experiment.

For scientific writing, report assay, assembly, resolution, normalisation, scale, QC and limitations.

Contents · Previous section · Next section

Section 34 of 36

34. Write a reader-ready HIC note

Name assay, assembly, file version, bins, resolution, normalisation, scale, QC and evidence limits.

Working checkpoint — matrix bin: Keep it beside the track. Separate indexed retrieval and contact enrichment from physical distance, regulation and causation.

For students, ask what each axis, bin and colour means before interpreting a pattern.

Contents · Previous section · Next section

Section 35 of 36

35. Build a validation ladder

Check version, assembly, bins, symmetry, normalisation, scale, hosting, retrieval and independent values.

Working checkpoint — normalization: Stop at the first unexplained cell. Treat assembly, bins, resolution and normalisation as scientific inputs: a silent change can reshape the matrix.

For parents, ask whether a striking heatmap keeps scale, controls and uncertainty visible.

Contents · Previous section · Next section

Section 36 of 36

36. Finish with a reproducible bundle

Deliver source pairs, pipeline, matrix settings, file hash, track stanza, QC and bounded interpretations.

Working checkpoint — three-dimensional genome: Make every bright cell traceable to an assay. Keep assay, sample, assembly, valid pairs, matrix-building pipeline, HIC version, resolutions, normalisation and scale together.

For a classroom model, use a small fictional symmetric matrix at two bin sizes.

Contents · Previous section · Continue to the Science Learning Hub